DEVELOPMENT AND CHARACTERISATION OF A PH-RESPONSIVE, COLOUR-CHANGING CMC–PVA BIOPOLYMER FILM WITH INTEGRATED GLUCOSE-SENSING CAPABILITY FOR VISUAL MONITORING OF WOUND INFECTION
1 Department of Pharmaceutics, Malla Reddy Institute of Pharmaceutical Sciences, Malla Reddy Vishwavidyapeeth (Deemed to be University), Maisammaguda, Dulapally, Secunderabad Hyderabad 500100, Telangana, India.
2 Pharm D 3rd Year Students from Malla Reddy Institute of Pharmaceutical Sciences, Malla Reddy Vishwavidyapeeth (Deemed to be University), Maisammaguda, Dulapally, Secunderabad Hyderabad 500100, Telangana, India.
3 Department of Pharmaceutical Chemistry, Malla Reddy Institute of Pharmaceutical Sciences, Malla Reddy Vishwavidyapeeth (Deemed to be University), Secunderabad, 500100, Telangana;
* Corresponding Author
ORCID Details
Nallagandla Rajitha: https://orcid.org/0009-0000-7396-6664
2 Pharm D 3rd Year Students from Malla Reddy Institute of Pharmaceutical Sciences, Malla Reddy Vishwavidyapeeth (Deemed to be University), Maisammaguda, Dulapally, Secunderabad Hyderabad 500100, Telangana, India.
3 Department of Pharmaceutical Chemistry, Malla Reddy Institute of Pharmaceutical Sciences, Malla Reddy Vishwavidyapeeth (Deemed to be University), Secunderabad, 500100, Telangana;
* Corresponding Author
ORCID Details
Nallagandla Rajitha: https://orcid.org/0009-0000-7396-6664
Research Article
International Journal of Biological and Pharmaceutical Sciences Archive, 2026, 12(02), 126–136.
Article DOI: 10.53771/ijbpsa.2026.12.2.0110
Publication history:
Received on 29 September 2026; revised on 05 November 2026; accepted on 07 November 2026
Abstract:
Wound pH shifts from the mildly acidic range of healing tissue (pH 4.0–6.0) to alkaline values (pH 7.0–9.0) during infection, often before overt clinical signs appear. Dressings that report this change visually could allow earlier intervention without removing the dressing.
Objective: To develop and characterize a pH-responsive, colour-changing carboxymethyl cellulose (CMC)–polyvinyl alcohol (PVA) film containing red cabbage anthocyanin and curcumin as a dual-dye indicator, and to integrate a low-cost glucose-sensing layer.
Methods: Three citric acid cross-linked films (F1, F2 and F3; CMC:PVA 1:2, 1:1 and 2:1) were prepared by solvent casting with glycerol and PEG-400 as plasticizers and alum as dye mordant. Dye pH response was recorded across pH 4–9. Films were evaluated for thickness, swelling in phosphate-buffered saline (PBS), and inhibition of heat-induced albumin denaturation as an in vitro anti-inflammatory screen. The F2 film was modified with an alginate–phenol red glucose-sensing layer (F2-BIO) cross-linked with CaCl₂ and coated with chitosan. Anti-biofilm activity against Escherichia coli was assessed by crystal violet assay.
Results: colour transitions across pH 4–9; thickness and swelling of F1–F3; % denaturation inhibition of F2 versus diclofenac; glucose-dependent colour change of F2-BIO; reduction in biofilm absorbance at 570 nm.]
Conclusion: The platform combines a visual pH read-out with a glucose channel in an inexpensive biopolymer matrix and offers a basis for smart wound dressings.
Keywords:
Smart Wound Dressing; pH Indicator; Anthocyanin; Curcumin; Carboxymethyl Cellulose; Polyvinyl Alcohol; Glucose Biosensor; Biofilm
Full text article in PDF:
Copyright information:
Copyright © 2026Author(s) retain the copyright of this article. This article is published under the terms of the Creative Commons Attribution Liscense 4.0